- The pressure sensor contact is normally closed.
- Place the pressure sensor on the irrigation line.
- Remove the pressure sensor cap.
- Check that the value is 0 by selecting the “instantaneous value” function connected via Bluetooth on the app.
- Activate watering and verify that the value has changed to 1.
- To set it precisely, during watering, screw the pressure sensor until you reach the value of 0.
- Then, still during watering, gently unscrew the pressure sensor until you reach the value 1 again.
- Note that you can also use a multimeter instead of using the instantaneous value.